WAEC 2010 Physics · Question 35

Which of the following factors will increase the sensitivity of moving coil meter?

Options

  1. A.strong spring
  2. B.low numbers of turns
  3. C.small area of coil
  4. D.soft iron core

Answer: D. soft iron core

Explanation written with AI and checked against the answer key

Analyze the question

Sensitivity of a moving coil galvanometer is the deflection produced per unit current:

θ/I = NBA / k

where

  • N = number of turns of the coil
  • B = magnetic flux density of the field
  • A = area of the coil
  • k = torsional constant (stiffness) of the hairsprings

Check each option

  • A. Strong spring: A large k reduces θ/I, so sensitivity decreases. ✗
  • B. Low number of turns: A small N reduces NBA/k, so sensitivity decreases. ✗
  • C. Small area of coil: A small A reduces NBA/k, so sensitivity decreases. ✗
  • D. Soft iron core: The soft iron cylinder sits inside the coil. It concentrates the magnetic field lines and makes the field radial and stronger (larger B) across the gap. A larger B increases NBA/k, so sensitivity increases. ✓

Correct answer: D, soft iron core

Exam tip: To increase sensitivity, make the top of the fraction big (N, B, A) and the bottom small (a weak spring). Remember "NBA over k". Any option that lowers N, B or A, or raises k, is wrong.