WAEC 2010 Physics · Question 35
Which of the following factors will increase the sensitivity of moving coil meter?
Options
- A.strong spring
- B.low numbers of turns
- C.small area of coil
- D.soft iron core
Answer: D. soft iron core
Explanation written with AI and checked against the answer key
Analyze the question
Sensitivity of a moving coil galvanometer is the deflection produced per unit current:
θ/I = NBA / k
where
- N = number of turns of the coil
- B = magnetic flux density of the field
- A = area of the coil
- k = torsional constant (stiffness) of the hairsprings
Check each option
- A. Strong spring: A large k reduces θ/I, so sensitivity decreases. ✗
- B. Low number of turns: A small N reduces NBA/k, so sensitivity decreases. ✗
- C. Small area of coil: A small A reduces NBA/k, so sensitivity decreases. ✗
- D. Soft iron core: The soft iron cylinder sits inside the coil. It concentrates the magnetic field lines and makes the field radial and stronger (larger B) across the gap. A larger B increases NBA/k, so sensitivity increases. ✓
Correct answer: D, soft iron core
Exam tip: To increase sensitivity, make the top of the fraction big (N, B, A) and the bottom small (a weak spring). Remember "NBA over k". Any option that lowers N, B or A, or raises k, is wrong.